A pumping test pumps 5400 L/min for 24 h from a well. Observation wells at 30 m and 90 m show drawdowns of 1.11 m and 0.53 m. Well diameter = 30 cm. Estimate drawdown in the pumped well (round off to 2 decimals), using steady–state flow and \(\pi = 3.14\).